Sunday, June 24, 2007

CMRC3 basic cleaning on June 23, 2007

On June 23, 2007, Adam Harrison and Madeline Weigner performed a basic cleaning of CMRC3.

Surface inspection and in-water inspection were performed. Brushing of support ropes and chains was also performed.

All items were in working order and accounted for except as noted here:

Part of one copper screen on the 1m CTD had come free of the body. It was pushed back into place.

We did not receive a replacement anode for the 1m CTD, so it is still missing an anode.

The remaining anodes on the CTD's are showing wear and are about halfway depleted.

One large anode on one support chain is severely deteriorating and is loose. it is still connected to the chain, but it will need to be replaced soon.

Fire coral is growing on some of the cables, beginning at 3m and extending to above the 1m CTD. I do not know if this is a problem or not, but I thought you ought to be made aware of it. If it is a problem, let us know and we will eradicate it when we perform a groundtruthing/full cleaning in 2 weeks.

Ciao,
AHarrison